Heat Pump Sizing & Low-Temperature Capacity Calculator
Heating delivery, demand and thermal balance point.
Calculate
The retention anchors represent generic system classes. Capacity tables at the design temperature govern actual equipment sizing; below −5°F the chart extends the final anchor slope, bounded at zero. EPA 608-certified technicians handle refrigerant circuits.
- Delivered heating capacity
- 10,800 BTU/h
- 47°F capacity retained
- 45 %
- Building heating demand
- 18,000 BTU/h
- Surplus / deficit
- -7,200 BTU/h
- Supplemental heat
- 7,200 BTU/h
- Resistance heat equivalent
- 2.11 kW
- Thermal balance point
- 15.29 °F
At the design temperature, supplemental heat covers the capacity deficit.
Calculation formulas
- Building UA = reference load / (65°F − reference temperature). Heating demand = UA × max(0, 65°F − outdoor temperature).
- Output = 47°F rating × piecewise retention (47°F: 100%; 17°F: 65% / 90%; 5°F: 45% / 80%; −5°F: 30% / 70%).
- Balance point solves delivered output = building demand; resistance supplement kW = positive deficit / 3,412.14163.
| Scenario | Delivered heating capacity | Building heating demand | Surplus / deficit |
|---|---|---|---|
| Standard at 5°F | 10,800 BTU/h | 18,000 BTU/h | -7,200 BTU/h |
| Cold-climate at 5°F | 19,200 BTU/h | 18,000 BTU/h | 1,200 BTU/h |
| Cold-climate at −15°F | 14,400 BTU/h | 24,000 BTU/h | -9,600 BTU/h |
Heating capacity at cold outdoor temperatures
A heat pump rated at 47°F delivers a fraction of its nameplate output as outdoor temperature falls. The generic standard and cold-climate curves interpolate between their four reference anchors; actual capacity tables identify equipment-specific low-ambient limits.
The thermal balance point
Building demand rises as the difference between the 65°F indoor balance setpoint and outdoor temperature grows. The intersection of building load and available heat pump output is the thermal balance point. Below it, the positive demand deficit is the supplemental heat requirement.
Cooling and heating equipment selection
Cooling load remains a separate capacity requirement, calculated from the room envelope and internal heat gains. A licensed electrician establishes supplemental heat circuit capacity, and EPA 608-certified HVAC technicians handle refrigerant connections.
Related calculators
Air Conditioner BTU & Room Size Calculator
Room cooling demand from area, envelope and internal heat gains.
Mini-Split Zone & System Capacity Calculator
Connected capacity, simultaneous output and minimum turndown.
Window Air Conditioner & Wall Sleeve Fit Calculator
Opening clearance, chassis geometry and outdoor airflow.
Air Conditioner Electricity, Amps & Cost Calculator
Running watts, power factor, circuit limits and monthly energy.
BTU, Tons & Watts Converter
Convert thermal capacity, electrical input and portable ratings.
SEER2 & CEER Energy Savings Calculator
Compare annual energy and ten-year utility savings.
AC Operating Cost Calculator
Seasonal cooling and delivered heating utility costs.
AC Backup Power Calculator
Generator starting load and battery runtime.
Garage AC BTU Calculator
Garage cooling load, door leakage and workshop equipment.