AC Backup Power Calculator
Generator starting load and battery runtime.
Calculate
Portable generators operate outdoors at least 20 ft from the home, with exhaust directed away from doors, windows and vents. A listed transfer switch or approved interlock installed by a licensed electrician isolates house wiring from utility power. Direct appliance connections use equipment-rated cords; household outlets never receive generator backfeed.
- Required steady load
- 1,200 W
- Peak startup load
- 3,200 W
- Running headroom
- 66.67 %
- Surge headroom
- 9.38 %
- Generator capacity
- Pass
Calculation formulas
- Steady load = AC running watts + concurrent load; startup load = AC running watts × startup multiplier + concurrent load.
- Headroom = (generator rating − required load) / required load × 100%. Both running and surge ratings must meet their respective load.
| Scenario | Required steady load | Peak startup load | Generator capacity |
|---|---|---|---|
| Fixed-speed compressor | 1,200 W | 3,200 W | Pass |
| Inverter soft-start | 1,200 W | 1,400 W | Pass |
| Lower surge rating | 1,200 W | 3,200 W | Fail |
Continuous and peak inverter ratings govern compatibility; energy capacity determines runtime at the entered load profile. Use the AC nameplate startup or locked-rotor rating when available.
- Average AC-side draw
- 900 W
- Average AC compressor draw
- 700 W
- Estimated energy runtime
- 1.89 hours
- Peak startup load
- 3,200 W
- Inverter compatibility
- Pass
Calculation formulas
- Average AC-side draw = running watts × duty + concurrent load.
- Runtime = usable battery Wh × conversion efficiency / average draw; charge falls linearly under the entered average load.
| Scenario | Average AC-side draw | Estimated energy runtime | Inverter compatibility |
|---|---|---|---|
| Fixed-speed compressor | 900 W | 1.89 hours | Pass |
| Inverter soft-start | 900 W | 1.89 hours | Pass |
| Larger battery | 900 W | 3.78 hours | Pass |
Generator running and startup ratings
The running requirement combines AC input watts and other outage loads. Fixed-speed compressor startup can require several times running wattage; inverter soft-start generally reduces the startup multiplier. Both generator ratings must accommodate the respective load, with nameplate locked-rotor or startup values taking precedence.
Battery energy and inverter compatibility
Usable battery watt-hours multiplied by the inverter conversion efficiency gives available AC-side energy. Average load combines compressor duty and concurrent loads. Runtime and continuous or surge output are separate requirements: battery capacity determines time, and inverter ratings determine power compatibility.
Outdoor generator and electrical separation
Portable generators run outdoors at least 20 ft from the home, with exhaust directed away from openings. A listed transfer switch or approved interlock installed by a licensed electrician isolates utility service from backup supply.
Related calculators
Air Conditioner BTU & Room Size Calculator
Room cooling demand from area, envelope and internal heat gains.
Mini-Split Zone & System Capacity Calculator
Connected capacity, simultaneous output and minimum turndown.
Window Air Conditioner & Wall Sleeve Fit Calculator
Opening clearance, chassis geometry and outdoor airflow.
Air Conditioner Electricity, Amps & Cost Calculator
Running watts, power factor, circuit limits and monthly energy.
BTU, Tons & Watts Converter
Convert thermal capacity, electrical input and portable ratings.
SEER2 & CEER Energy Savings Calculator
Compare annual energy and ten-year utility savings.
Heat Pump Sizing & Low-Temperature Capacity Calculator
Heating delivery, demand and thermal balance point.
AC Operating Cost Calculator
Seasonal cooling and delivered heating utility costs.
Garage AC BTU Calculator
Garage cooling load, door leakage and workshop equipment.