AC Operating Cost Calculator
Seasonal cooling and delivered heating utility costs.
Calculate
Compare the same rating basis and delivered cooling load. A 30-day month within the season uses the selected daily profile.
- Daily energy
- 6.72 kWh
- Monthly energy
- 201.6 kWh
- Seasonal energy
- 806.4 kWh
- Daily cost
- 1.08 USD
- Monthly cost
- 32.26 USD
- Seasonal cost
- 129.02 USD
- Fixed-speed seasonal energy
- 806.4 kWh
- Inverter seasonal energy
- 537.6 kWh
- Fixed-speed seasonal cost
- 129.02 USD
- Inverter seasonal cost
- 86.02 USD
Calculation formulas
- Daily kWh = BTU/h / efficiency / 1,000 × hours/day × duty.
- Season energy = daily kWh × days; bill = energy × utility rate.
| Scenario | Daily energy | Seasonal energy | Seasonal cost |
|---|---|---|---|
| Fixed-speed | 6.72 kWh | 806.4 kWh | 129.02 USD |
| Inverter | 4.48 kWh | 537.6 kWh | 86.02 USD |
| Long season | 6.72 kWh | 1,209.6 kWh | 193.54 USD |
Heating fuel inputs use 100,000 BTU/therm for natural gas and 91,500 BTU/gal for propane; AFUE is the delivered fraction. Electric resistance has COP 1.
- Delivered seasonal demand
- 20 MMBtu
- Heat pump COP
- 2.34
- Heat pump electricity
- 2,500 kWh
- Heat pump delivered cost
- 20 USD/MMBtu
- Comparison delivered cost
- 16.67 USD/MMBtu
- Heat pump seasonal cost
- 400 USD
- Comparison seasonal cost
- 333.33 USD
Calculation formulas
- COP = HSPF2 / 3.41214163; heat pump kWh = MMBtu × 1,000,000 / (3,412.14163 × COP).
- Fuel cost per delivered MMBtu = fuel rate × 1,000,000 / (fuel BTU per unit × AFUE). Seasonal cost = delivered cost per MMBtu × demand.
| Scenario | Heat pump delivered cost | Comparison delivered cost | Comparison seasonal cost |
|---|---|---|---|
| Natural gas | 20 USD/MMBtu | 16.67 USD/MMBtu | 333.33 USD |
| Propane | 20 USD/MMBtu | 18.21 USD/MMBtu | 364.3 USD |
| Electric resistance | 20 USD/MMBtu | 46.89 USD/MMBtu | 937.83 USD |
Cooling energy across a season
A fixed-speed compressor cycles at full input, while an inverter can modulate its output. The entered efficiency and equivalent duty factors establish comparable energy profiles. Daily energy multiplied by season days gives seasonal kWh; a 30-day interval gives the monthly equivalent.
Heating fuel comparison
Cost per delivered MMBtu places electricity, natural gas and propane on a common heat-output basis. Heat pump COP expresses delivered thermal energy per electrical input, while AFUE expresses the fraction of fuel energy delivered to the conditioned space.
Planning and installation
Utility comparisons use the entered rates and delivered heating demand. Nameplate electrical supply, fuel appliance requirements and refrigerant circuit commissioning belong to licensed electrical and HVAC installation.
Related calculators
Air Conditioner BTU & Room Size Calculator
Room cooling demand from area, envelope and internal heat gains.
Mini-Split Zone & System Capacity Calculator
Connected capacity, simultaneous output and minimum turndown.
Window Air Conditioner & Wall Sleeve Fit Calculator
Opening clearance, chassis geometry and outdoor airflow.
Air Conditioner Electricity, Amps & Cost Calculator
Running watts, power factor, circuit limits and monthly energy.
BTU, Tons & Watts Converter
Convert thermal capacity, electrical input and portable ratings.
SEER2 & CEER Energy Savings Calculator
Compare annual energy and ten-year utility savings.
Heat Pump Sizing & Low-Temperature Capacity Calculator
Heating delivery, demand and thermal balance point.
AC Backup Power Calculator