Calculators / Interactive calculator

AC Operating Cost Calculator

Seasonal cooling and delivered heating utility costs.

Engineering workspace

Calculate

Seasonal cooling cost

Compare the same rating basis and delivered cooling load. A 30-day month within the season uses the selected daily profile.

Cooling energy and utility comparisonSeasonal cooling comparisonFixed-speed energy806.4 kWhInverter energy537.6 kWhFixed-speed bill129 USDInverter bill86 USD
Daily energy
6.72 kWh
Monthly energy
201.6 kWh
Seasonal energy
806.4 kWh
Daily cost
1.08 USD
Monthly cost
32.26 USD
Seasonal cost
129.02 USD
Fixed-speed seasonal energy
806.4 kWh
Inverter seasonal energy
537.6 kWh
Fixed-speed seasonal cost
129.02 USD
Inverter seasonal cost
86.02 USD
Calculation formulas
  • Daily kWh = BTU/h / efficiency / 1,000 × hours/day × duty.
  • Season energy = daily kWh × days; bill = energy × utility rate.
Scenario comparisons
ScenarioDaily energySeasonal energySeasonal cost
Fixed-speed6.72 kWh806.4 kWh129.02 USD
Inverter4.48 kWh537.6 kWh86.02 USD
Long season6.72 kWh1,209.6 kWh193.54 USD

Cooling energy across a season

A fixed-speed compressor cycles at full input, while an inverter can modulate its output. The entered efficiency and equivalent duty factors establish comparable energy profiles. Daily energy multiplied by season days gives seasonal kWh; a 30-day interval gives the monthly equivalent.

Heating fuel comparison

Cost per delivered MMBtu places electricity, natural gas and propane on a common heat-output basis. Heat pump COP expresses delivered thermal energy per electrical input, while AFUE expresses the fraction of fuel energy delivered to the conditioned space.

Planning and installation

Utility comparisons use the entered rates and delivered heating demand. Nameplate electrical supply, fuel appliance requirements and refrigerant circuit commissioning belong to licensed electrical and HVAC installation.

Related calculators

Engineering reference tables →