BTU, Tons & Watts Converter
Convert thermal capacity, electrical input and portable ratings.
Calculate
Thermal kW describes heat moved; running watts describe electricity consumed. DOE SACC is the portable purchase capacity.
- Cooling capacity
- 12,000 BTU/h
- Refrigeration tons
- 1 tons
- Thermal cooling
- 3.52 kW
- Running power
- 1,000 W
- Apparent current
- 9.45 A
- DOE SACC range
- 7,700–10,500 BTU/h
Calculation formulas
- 1 ton = 12,000 BTU/h = 3.51685 kW; 1 kW = 3,412.14163 BTU/h.
- Running watts = BTU/h / EER or CEER; apparent amps = watts / (voltage × PF).
- DOE SACC = ASHRAE × 0.55 to × 0.75; reverse range = SACC / 0.75 to / 0.55.
| Scenario | Cooling capacity | Refrigeration tons | Running power |
|---|---|---|---|
| One ton | 12,000 BTU/h | 1 tons | 1,000 W |
| Two tons | 24,000 BTU/h | 2 tons | 2,000 W |
| Thermal kW | 17,060.71 BTU/h | 1.42 tons | 1,421.73 W |
Thermal capacity versus electrical input
Refrigeration tons, BTU/h and thermal kilowatts express heat transfer. One refrigeration ton is 12,000 BTU/h or 3.51685 kW of cooling. At a CEER of 12, that thermal output corresponds to 1,000 W of electrical input. Voltage and power factor determine apparent amperage.
Portable air conditioner rating translation
DOE SACC represents net cooling after portable exhaust and infiltration losses. A typical legacy single-hose rating of 14,000 BTU/h ASHRAE corresponds to 7,700–10,500 BTU/h SACC. DOE SACC governs capacity selection.
Planning and equipment supply
Thermal units support room load planning. Actual electrical compatibility uses the nameplate current and listed plug or MCA/MOP supply requirements. Licensed electricians establish hardwired circuit capacity.
Related calculators
Air Conditioner BTU & Room Size Calculator
Room cooling demand from area, envelope and internal heat gains.
Mini-Split Zone & System Capacity Calculator
Connected capacity, simultaneous output and minimum turndown.
Window Air Conditioner & Wall Sleeve Fit Calculator
Opening clearance, chassis geometry and outdoor airflow.
Air Conditioner Electricity, Amps & Cost Calculator
Running watts, power factor, circuit limits and monthly energy.
SEER2 & CEER Energy Savings Calculator
Compare annual energy and ten-year utility savings.
Heat Pump Sizing & Low-Temperature Capacity Calculator
Heating delivery, demand and thermal balance point.
AC Operating Cost Calculator
Seasonal cooling and delivered heating utility costs.
AC Backup Power Calculator
Generator starting load and battery runtime.
Garage AC BTU Calculator
Garage cooling load, door leakage and workshop equipment.