What Is Relative Humidity (RH)?

Relative humidity (RH) measures the amount of water vapor currently in the air as a percentage of the maximum water vapor that air can hold at the same dry-bulb temperature. It does not measure the total mass of moisture in the air or the dew point temperature. Because saturation capacity rises and falls with temperature, air can become more humid in percentage terms even as an air conditioner lowers its temperature without removing moisture.

How Is Relative Humidity Calculated?

Relative humidity equals the actual water-vapor pressure divided by the saturation vapor pressure at the current air temperature, multiplied by 100%.

  • Formula: RH (%) = (Actual_Vapor_Pressure / Saturation_Vapor_Pressure_at_T) * 100
  • Units: Percentage (%), always tied to a specific dry-bulb temperature (°F).

Warm air has a higher saturation vapor pressure than cold air, meaning it can hold more water vapor before reaching 100% RH. When air reaches 100% RH, it is saturated at its dew point, and any further cooling forces water vapor to condense into liquid water.

How Does Temperature Shift Relative Humidity Without Changing Moisture?

Lowering air temperature raises relative humidity whenever no moisture is removed, because the air's saturation vapor pressure drops as it cools.

For example, if air at 78 °F and 50% RH is cooled toward 70 °F without condensing water onto an evaporator coil, its RH climbs into the mid-60% range even though the actual water-vapor content stays identical. Conversely, bringing cool 50 °F outdoor air inside and heating it to 70 °F lowers its indoor RH percentage without removing a single drop of moisture.

What Are the Practical RH Boundaries for Room Cooling?

Relative humidity dictates whether evaporative cooling is viable and whether a refrigerated air conditioner will maintain comfort alongside temperature control.

Condition / Threshold Engineering Effect Practical Selection Impact
Outdoor RH above ~50% Evaporation slows sharply as air nears saturation Windowless evaporative coolers stop cooling effectively; choose a refrigerated AC type instead
Sensible cooling without coil condensation Air temperature drops while moisture stays constant, pushing indoor RH upward Short-cycling an oversized unit leaves rooms cool and clammy; match capacity using the BTU Calculator
100% RH (Dew Point) Air is fully saturated; excess vapor condenses on cold surfaces Evaporator coils must run long enough below dew point to drain condensate outside

Properly sized refrigerated units balance sensible cooling (lowering °F) with latent cooling (condensing water vapor). Review room AC sizing guidance and common room AC problems if a space reaches target temperature quickly but remains sticky.

What Are Common Misreadings of Relative Humidity?

Treating relative humidity as a direct measurement of total water in the air causes equipment mismatches and misdiagnosed comfort issues.

  • Equating RH with absolute moisture: 60% RH at 85 °F contains substantially more water vapor than 60% RH at 65 °F.
  • Assuming cooler air is always drier: Dropping room temperature without sufficient compressor run time raises indoor RH rather than lowering it.
  • Ignoring outdoor RH for evaporative units: An evaporative cooler rated for dry climates loses its temperature-drop performance once outdoor RH climbs past ~50%.
  • BTU Calculator for matching cooling capacity to room area and heat-gain modifiers
  • AC Types Overview for comparing refrigerated room units against evaporative limits
  • Air Density for how temperature and moisture affect air mass per cubic foot
  • HVAC Glossary for additional psychrometric and electrical definitions